All Categories
    Menu Close

    Differential Scanning Calorimeters

    View as Grid List
    Sort by
    Display per page
    Digital Differential Scanning Calorimeter, Cooling Scan

    Digital Differential Scanning Calorimeter, Cooling Scan

    SISCO-DSC-HNB
    High accurate differential scanning calorimeter for sale, comes with air cooling, semiconductor cooling, liquid nitrogen cooling. The differential scanning calorimetry machine can test glass transition temperature/enthalpy/crystallization/melting, and use a digital gas mass flowmeter to accurately control the purge gas flow. Differential scanning calorimeter equipment measures the relationship between temperature and heat flow related to thermal transition inside the material and is widely used in materials science, chemistry, pharmacy, food science, and other fields.
    $8,082.35
    DSC Differential Scanning Calorimeter, High Temperature

    DSC Differential Scanning Calorimeter, High Temperature

    SISCO-DSC-TGA
    Differential scanning calorimeter with high-temperature analysis, equipped with a USB interface and software settings, the STA scanning calorimeter has PID algorithm controls. The digital scanning calorimeter comes with a built-in gas flow meter, which can switch two-way gas. The thermogravimetric analyzer can be operated remotely through computer software. The scanning calorimeter STA/TGA with a 7-inch 24BIT touch screen, usually applied for studying the thermal and oxidative stability of polymer materials.
    $20,543.86
    DSC Differential Scanning Calorimeter, Touch Screen

    DSC Differential Scanning Calorimeter, Touch Screen

    SISCO-DSC-HM
    The differential calorimeter for sale, a differential scanning calorimetry machine with an 8/15 inch touch screen, and a 110V/220V AC power supply can be optional. The temperature range reaches room temperature-500℃, USB interface, and heating and constant temperature can be automatically controlled by the program. Equipped with a digital flow meter, more precise airflow can be controlled by a digital scanning calorimeter. DSC can test glass transition temperature, phase transition, melting and thermal enthalpy, thermal stability, and oxidation induction period.
    $8,448.08

    A differential scanning calorimeter is a thermal analysis instrument. It is mainly used in materials science, chemistry, biology, drug development, food industry, and energy fields. Differential scanning calorimeters can also be used to measure the melting point, boiling point, and other properties of solid and liquid materials.

    1. Inorganic substances: such as metals, minerals, and ceramics.
    2. Organic compounds: including various organic materials and polymers.
    3. Drugs: used for thermal analysis of drugs, such as reaction heat, transition heat, etc.
    4. Polymer materials: study their crystallization, melting temperature and thermal effects, as well as glass transition temperature, etc.
    5. Fiber materials: can be made into 1~2mm length for testing.
    6. Powder samples: need to be compacted and ensure that they are not less than 20mg.

    Working principle of scanning calorimeter

    The differential scanning calorimeter on the SISCO website studies the physical and chemical changes of substances by comparing the heat difference between the sample and the reference at a program-controlled temperature. Specifically, it measures the relationship between the energy difference (or power difference) input into the sample and the reference per unit time and the temperature change.

    Application scope

    The application scope of the differential calorimeter is very wide, especially suitable for the study of the curing reaction temperature and thermal effect of polymer materials, the phase change temperature and its thermal effect determination of materials, the crystallization and melting temperature and its thermal effect determination of polymer materials, and the glass transition temperature of polymer materials. In addition, it can also be used to detect the phase transition and thermal enthalpy change of solid or liquid samples during constant temperature or variable temperature and is widely used to characterize polymer materials, rubber, fabrics, food, medicine, cosmetics, and other materials.

    Main features

    1. New furnace structure: better resolution and better baseline stability
    2. Digital gas mass flowmeter: precise control of purge gas flow, data directly recorded in the database
    3. Instrument control: bidirectional control (host control, software control) is available, with a friendly interface and easy operation
    4. Powerful data processing capability: The differential scanning calorimeter is equipped with advanced data processing software, which can automatically record and analyze experimental data. Users can easily obtain key information such as the sample's enthalpy, melting point, glass transition temperature, etc.
    5. Multiple test modes: The digital differential calorimeter supports multiple test modes, such as dynamic scanning, static scanning, isothermal scanning, etc. This makes DSC suitable for different types of samples and test requirements.