All Categories
    Menu Close

    Digital Heated Magnetic Stirrer for Laboratory, 5L

    The SISCO digital heated magnetic hotplate stirrer offers precise speed control (200–2000 rpm) and powerful 600W heating, making it ideal for a wide range of lab applications. The intuitive digital display and smart button controls of this magnetic stirrer ensure easy operation. Its 19x19 cm ceramic-coated plate is corrosion-resistant and supports up to 5L of stirring volume. With temperatures up to 380°C, this lab magnetic stirrer is perfect for use in chemical engineering, university research, and biopharmaceutical laboratories.
    SKU: SISCO-MS-HSC-19T
    *
    $563.85
    i h
    🚚 Free shipping
    🔙 30-day returns
    📅 Delivery: 7-12 days
    Overview

     

    Our digital magnetic hotplate stirrer delivers powerful and stable performance for laboratory heating and mixing. With strong magnetic coupling and adjustable stirring speed, it ensures smooth, quiet operation across various experiments. The corrosion-resistant ceramic-coated hotplate heats quickly and evenly, ideal for handling chemical solutions. A built-in temperature probe of this lab hotplate stirrer enables precise thermal control, while the digital control panel allows easy adjustment of speed, time, and temperature.

    Lab digital heated magnetic stirrer 5l backside chart

    Precision Heating & Efficient Stirring

    • Digital temperature control with stable stirring. Reaching up to 380°C, this digital heated magnetic stirrer hot plate allows clear, repeatable thermal settings to ensure consistent lab conditions.
    • Powerful magnetic field for stable mixing. The internal high-performance magnet of this magnetic mixer ensures the magnetic stir bar remains centered and stable during operation—preventing dislodgement and improving experiment reliability.
    • Wide speed range for diverse applications. With a stirring speed of 200–2000 rpm, this lab magnetic stirrer can handle everything from corrosive chemical solutions to high-purity liquids.
    Lab digital heated magnetic stirrer 5l front view

    Smart Temperature Control & Flexible Stirring for Laboratory Safety

    • Dual temperature control modes. Users can switch between liquid temperature control and surface temperature control depending on the experiment, enabling greater accuracy and flexibility.
    • Over-temperature protection for lab safety. SISCO digital magnetic hotplate stirrer supports an independent safety circuit that automatically cuts off heating when the plate exceeds safe limits, protecting both users and equipment.
    • Stepless speed regulation. Smooth low speeds for delicate mixing and strong high speeds for vigorous agitation—the stepless control ensures flexible, efficient stirring in any lab setting.

    Applications

    Magnetic stirrers are widely used in scientific and industrial settings such as university labs, chemical engineering, biopharmaceuticals, and clinical laboratories. In research and education, they enable hands-free mixing for experiments and training. In chemical and pharmaceutical fields, magnetic hotplate stirrers offer precise control of temperature and speed, ideal for synthesis, titration, and reagent preparation. In clinical labs, they help maintain consistent stirring of diagnostic samples, ensuring accurate and repeatable results. These versatile tools enhance efficiency, consistency, and reliability across a range of applications.

    Magnetic stirrer for chemical engineering

     Chemical Engineering

    Magnetic stirrer for biopharmaceuticals

    Biopharmaceuticals

    Magnetic stirrer for medical and healthcare

    Medical & Healthcare

    Magnetic stirrer for unversity research

    University Research

    Specs

     

    Model SISCO-MS-HSC-19T
    Functions Digital temperature control & Heating & Stirring
    Control Method Smart buttons
    Heating Power 600W
    Voltage AC 220V or 110V
    Max Stirring Volume 5L
    Speed Range 200–2000 rpm
    Display LED Screen
    Digital Temperature Control Temperature Probe
    Working Plate Size 19×19 cm
    Working Plate Temperature Room temperature~380°C
    Working Plate Material Anti-corrosion ceramic plate
    Weight 5.2 kg

     

    Details

    Lab digital heated magnetic stirrer 5l operation panel analysis

    FAQs

    Q1: What is the advantage of a magnetic stirrer?
    A1: A magnetic stirrer uses a magnetic field to drive a stir bar, enabling contact-free mixing that eliminates seal leakage issues common in traditional mechanical stirrers. With adjustable stirring speeds and smooth operation, it minimizes splashing and air bubble formation. When equipped with a digital temperature control function, the heated magnetic stirrer maintains precise heating conditions, improving experiment reproducibility. Its compact design and ease of use make it ideal for sterile and cleanroom environments. A laboratory magnetic stirrer is an essential laboratory mixing tool for accurate temperature control and efficient liquid handling in chemical, biological, and pharmaceutical labs.

    Q2: What is the difference between a magnetic stirrer and a hot plate?
    A2: A magnetic stirrer is designed to mix liquids using a rotating magnetic field and typically includes variable speed and digital temperature control, making it ideal for laboratory applications requiring uniform mixing and precise heating. A hot plate, on the other hand, only provides surface heating without stirring capability and is used for simple heating or melting tasks. For advanced laboratory experiments, a magnetic hotplate stirrer combines both functions, offering both controlled mixing and heating in one device, perfect for chemistry, biology, and material science applications.

    Q3: What precautions should be taken when using a magnetic stirrer with a hot plate?
    A3: Ensure that the container is made of heat-resistant material and has a flat bottom to avoid uneven heating. Regularly check the synchronization between the stir bar and magnetic field to prevent slippage or disengagement. Set a maximum temperature limit and use the overheat protection feature to avoid boiling or dry burning. Wear heat-resistant gloves during operation, keep flammable materials away, and ensure proper ventilation. After use, turn off the power and allow the unit to cool before cleaning to avoid burns or equipment damage.

    Tips: What to do if the magnetic stirrer heats unevenly or the stir bar doesn’t spin?

    • Check if the container is properly centered and in full contact with the hotplate.
    • Ensure the bottom of the container is flat and undamaged—replace if necessary.
    • Inspect the magnetic stir bar for demagnetization (common after prolonged high-temperature use); replace if needed.
    • Keep the distance between the hotplate surface and the stir bar within 5mm to maintain magnetic strength.
    • Evaluate the viscosity of the liquid and the size of the stir bar—adjust the stirring speed or switch to a more suitable stir bar if needed.
    Warranty

    Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.


    What is covered?

    SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.


    What is not covered?

    • Product purchased from anyone other than a SISCO store or a SISCO authorized reseller.
    • Expendable parts.
    • Routine cleaning or normal cosmetic and mechanical wear.
    • Damage from misuse, abuse or neglect.
    • Damage from use of parts other than SISCO approved.
    • Damage from use outside the product’s usage or storage parameters.
    • Damage from use of parts not sold by SISCO.
    • Damage from modification or incorporation into other products.
    • Damage from repair or replacement of warranted parts by a service provider other than a SISCO authorized service provider.
    • Damage caused by the application environment not meeting the product usage requirements and the failure to perform preventive maintenance.
    0.0 0
    Write your own review Close
    *
    *