All Categories
    Menu Close

    Table Top Steam Sterilizer, 18L/23L

    The table top steam sterilizer features a high-quality stainless steel inner tank with a sealed cover, microcomputer-controlled automatic cycle. Ideal for use in healthcare settings, laboratories, dental clinics, beauty salons, and research facilities.
    SKU: SISCO-TTSS-18B
    *
    *
    $1,832.81
    i h
    🚚 Free shipping
    🔙 30-day returns
    📅 Delivery: 7-12 days
    Overview

    The table top steam sterilizer is a high-performance, safe, and reliable device with automatic controls and adjustable settings for 121℃ and 134℃. Meeting European CLASS B and EN13060 standards, it offers rapid sterilization for a variety of steam-resistant items in healthcare, research, and pharmaceutical industries.

    Table top steam sterilizer

    High-quality stainless steel inner tank with sealed cover.

    • Designed with a built-in safety interlocking mechanism to ensure secure operation, preventing accidental opening during the sterilization cycle for enhanced user safety.
    • The sterilizer offers intuitive touch-button operation, making it easy to set, monitor, and control the sterilization cycle, ensuring a user-friendly experience.
    Table top steam sterilizer detail

    Standard Test Interface and Open-Top Water Tank Design

    • To prevent internal air leakage, the steam sterilizer is equipped with a replaceable sealing ring.
    • SISCO table top steam sterilizer is equipped with a standard test interface for performance verification, and an open-top water tank design for convenient maintenance and water level monitoring.

    Applications

    SISCO sterilizer is a safe, reliable, and automatically controlled rapid tabletop device, meeting the European CLASS B and EN13060 standards. With high performance, reliability, and safety, its triple-pulse vacuum design makes it an advanced and cost-effective solution for medical, pharmaceutical, and research industries. It provides rapid sterilization for steam-resistant items such as surgical, dental, ophthalmic instruments, pharmaceuticals, culture media, fabrics, and food.

    Table top steam sterilizer for healthcare

    Healthcare

    Table top steam sterilizer for experiment

    Experiment

    Table top steam sterilizer for operation

    Operation

    Table top steam sterilizer for pharmaceutical industry

    Pharmaceutical Industry

    Specs

     

    Model SISCO-DGT-18B SISCO-DGT-23B
    Volume 18L 23L
    Power 2.2kw 2.2kw
    Voltage 110V/220V, 60Hz/50HZ
    Rated working pressure 0.22MPa
    Rated working temperature 134℃
    Chamber volume Ø250×370 Ø250×452
    Outer dimension 480×590×450 480×690×450
    Packing size(L×W×H) 670×560×510 760×560×510
    Gross/net weight 57/48KG 60/53KG

     

    Details

    Table top steam sterilizer details

    FAQs

    Q1: What is a table top steam sterilizer?
    A1: A table top steam sterilizer is a compact device that uses pressurized steam at high temperatures to sterilize instruments and tools, eliminating harmful microorganisms. It's commonly used in healthcare, laboratories, and dental clinics, offering efficient, space-saving sterilization with user-friendly controls and safety features.

    Q2: Which materials should not be sterilized?
    A2: Oils, waxes, plastic, rubber, or electronic components, flammable materials, radioactive materials, andsamples containing solvents, substances that can release harmful fumes when exposed to high heat should also be avoided.

    Q3: What is the difference between an autoclave and a sterilizer?
    A3:
    An autoclave is a specific type of sterilizer that uses steam and pressure to kill germs. A sterilizer is any device that kills germs, and it can use steam, heat, chemicals, or other methods. So, all autoclaves are sterilizers, but not all sterilizers are autoclaves.

    Tips: How to properly use a sterilizer?

    • Prepare items: Clean and dry the items to be sterilized, as dirt or moisture can affect the sterilization process.
    • Load properly: Arrange items in the sterilizer in a way that allows steam or sterilizing agents to reach all surfaces. Avoid overcrowding.
    • Set the correct cycle: Choose the appropriate temperature, time, and cycle settings based on the sterilizer type and materials you're sterilizing.
    • Start the cycle: Turn on the sterilizer and allow it to complete the cycle without opening it prematurely.
    • Cool and unload: After the cycle finishes, allow the items to cool before handling. Ensure they are completely dry and safe to use.
    • Regular maintenance: Clean and maintain the sterilizer regularly to ensure it works efficiently.

    Always follow the manufacturer's instructions for your specific sterilizer model.

    Warranty

    Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.


    What is covered?

    SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.


    What is not covered?

    • Product purchased from anyone other than a SISCO store or a SISCO authorized reseller.
    • Expendable parts.
    • Routine cleaning or normal cosmetic and mechanical wear.
    • Damage from misuse, abuse or neglect.
    • Damage from use of parts other than SISCO approved.
    • Damage from use outside the product’s usage or storage parameters.
    • Damage from use of parts not sold by SISCO.
    • Damage from modification or incorporation into other products.
    • Damage from repair or replacement of warranted parts by a service provider other than a SISCO authorized service provider.
    • Damage caused by the application environment not meeting the product usage requirements and the failure to perform preventive maintenance.
    0.0 0
    Write your own review Close
    *
    *