Double beam UV vis spectrophotometer can accurately measure the absorption spectrum of substances in the ultraviolet and visible light regions, is easy to operate, uses imported tungsten lamps and imported tungsten lamps and deuterium lamps, has a long service life, does not require preheating, and has good stability.
Accurate Measurement
Quality Assurance
Spectrophotometers are widely used in many industries due to their high accuracy, good reproducibility, and simple operation. Spectrophotometers can be used to measure the optical constants of materials, such as refractive index, absorption coefficient, scattering coefficient, etc., and can analyze the composition and structure of materials. In the pharmaceutical process, spectrophotometers can be used for drug purity testing, content determination, stability research, etc. Spectrophotometers can be used to measure the content of various pollutants in water and the concentration of pollutants in the air, and can also analyze the nutrient content and heavy metal content in the soil. Spectrophotometers can be used in conjunction with cuvettes and flow injection systems for complex system analysis.
Â
Model | SISCO-PS-EU03 | SISCO-PS-EU04 |
Spectral Bandwidth | 1.8nm | |
Wavelength Range | 190~1100nm | |
Optical System | Quasi-dual beam ratio monitoring optical path, holographic diffraction grating | |
Wavelength Accuracy | ±0.1nm(656.1nm);±0.3nm (All regions) | |
Wavelength Repeatability | ≤0.1nm | |
Wavelength Setting | Automatic wavelength setting, wavelength resolution 0.1nm | |
Photometric Range | 0~200%T, -4~4A, 0~9999C, 0~9999F | |
Photometric Accuracy | ±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.3%T (0~100%T) | ±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.2%T (0~100%T) |
Photometric Repeatability | ≤0.001A (0~0.5A), ≤0.002A (0.5~1A), ≤0.1%T (0~100%T) | |
Stray Light | ≤0.03%T (220/360nm) | |
Baseline Drift (Stability) | ≤0.001A/h (500nm,0A) | ≤0.004A/h (500nm,0A) |
Noise | ±0.1%T (0%T line); ±0.3%T (100%T line); ±0.0005A (at 500nm) | ±0.1%T (0%T line); ±0.3%T (100%T line); ±0.0004A (at 500nm) |
Baseline Straightness | ±0.0015A | ±0.001A |
Scanning Speed | High, medium, and low speed three gears are adjustable | |
Detector | Imported silicon photodiode | |
Light Source | Imported long-life tungsten lamp and deuterium lamp (optical adjustment-free) | |
Display | 6-inch 320x240 dot matrix LCD | |
Keyboard | Digital touch membrane button | |
Data Interface | USB | |
Printout | Micro printer; PC printer (online use) | |
PC Software | PC scanning analysis software (standard) | |
Power Supply | AC 90~250V, 50/60Hz | |
Dimensions | 63.5cm×51.5cm×25.5cm | |
Weight | 26kg |
A1:Â What is the difference between a UV-Visible spectrophotometer and a visible spectrophotometer?
Q1:Â The difference between UV-Visible spectrophotometer and visible spectrophotometer is that the measurement wavelength range is different, UV generally uses a hydrogen lamp, the measurement wavelength range is of 180 ~ 350NM, visible generally uses a tungsten lamp, and the measurement wavelength range of 320 ~ 1000NM. The so-called UV-Visible spectrophotometer also means that this instrument can change the light source, can determine the absorption peak in the UV and visible part of the compound.
A2:Â What is the wavelength range of the UV-Visible spectrophotometer?
Q2:Â Ultraviolet-visible (UV-Vis) spectrophotometers use a light source that illuminates the sample with light in the UV to visible wavelength range (typically 190 to 900 nm). UV-Vis-NIR spectrophotometers extend the wavelength range to the near-infrared (NIR) (800 to 3200 nm).
A3:Â What is the principle of operation of a spectrophotometer?
Q3:Â The basic principle of the spectrophotometer is that the substances in solution are excited by light irradiation, resulting in the effect of light absorption, the absorption of light by substances is selective, a variety of different substances have their own absorption spectrum, so when a monochromatic light through the solution, its energy will be absorbed and diminished, the degree of light energy diminution and the concentration of substances have a certain proportional relationship, that is, in line with the colorimetric principle - -Biel's law.Â
Tips: DailyMaintenance of Spectrophotometer
Spectrophotometers are widely used in many industries due to their high accuracy, good reproducibility, and simple operation. Spectrophotometers can be used to measure the optical constants of materials, such as refractive index, absorption coefficient, scattering coefficient, etc., and can analyze the composition and structure of materials. In the pharmaceutical process, spectrophotometers can be used for drug purity testing, content determination, stability research, etc. Spectrophotometers can be used to measure the content of various pollutants in water and the concentration of pollutants in the air, and can also analyze the nutrient content and heavy metal content in the soil. Spectrophotometers can be used in conjunction with cuvettes and flow injection systems for complex system analysis.
Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.
SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.