This SISCO multifunctional process calibrator has an open-source communication protocol features a large LED screen for multiple data displays, which can simultaneously show: DC current and% value, thermocouple, thermal resistance temperature and their corresponding division values, etc. It can also be equipped with high-precision temperature probes, with an accuracy of ± 0.2 ℃. It can output various process parameter signals to meet most of the on-site debugging and maintenance needs.
Characteristics of a multifunctional process calibrator
Introduction of a multifunctional process calibrator
SISCO process calibrators are widely used in various industries, including manufacturing to ensure the accuracy of sensors in automated systems. Pharmaceuticals: maintaining compliance with strict temperature and pressure regulations. Energy and utilities testing electrical and pressure instruments in power plants and pipelines. Aerospace verifying flight instruments and environmental control systems. Food and beverage to ensure accurate temperature control in processing and storage.
Â
Model | SISCO-PC-VICTOR11+ | ||||
Function | Range | Output setting range | Resolution | Accuracy | Notes |
DCV | 100mV | -10.000~110.000mV | 1μV | 0.02+0.01 | Maximum output current 0.5mA |
1000mV | -100.00~110.000mV | 10μV | Maximum output current 2mA | ||
10mV | -1.0000~11.0000V | 0.1mA | Maximum output current 5mA | ||
DCmA | 20mA | 0.000~22.000mA | 1μA | 0.02+0.02 | At 20mA, when simulating a transmitter with a maximum load of 1 KΩ resistor, the external power supply is 5-28V |
OHM | 400Ω | 0.00Ω~400.00Ω | 0.01Ω | 0.02+0.02 | The excitation current is ± 0.5~3mA/excitation current is ± 0.1~0.5mA, and the accuracy does not include lead resistance |
4KΩ | 0.0000KΩ~4.0000KΩ | 0.1Ω | 0.05+0.025 | The excitation current is ± 0.05~3mA, and the accuracy does not include lead resistance | |
40KΩ | 0.000KΩ~40.000KΩ | 1Ω | 0.1+0.1 | The excitation current is ± 0.01mA, and the accuracy does not include lead resistance | |
TC | R | 0℃~1767℃ | 1℃ |
0~100℃: 1.5℃ 100~1767℃: 1.2℃ |
The accuracy of ITS-90 temperature scale does not include the error of cold end compensation |
S | 0℃~1767℃ | 0~100℃: 1.5℃      100~1767℃: 1.2℃ | |||
K | -200.00℃~1372.0℃ | 0.1℃ | -200.0~100.0℃: 0.6℃ -100.0~400.0℃: 0.5℃ 400.0~1200.0℃: 0.7℃ 1200.0~1372.0℃: 0.9℃ | ||
E | -200.00℃~1000.0℃ | -200.0~-100.0℃: 0.6℃ -100.0~600.0℃: 0.5℃     600.0~1000.0℃: 0.4℃ | |||
J | -200.00℃~1200.0℃ | -200.0~-100.0℃: 0.6℃    -100.0~800.0℃: 0.5℃     800.0℃~1200.0℃: 0.7℃  | |||
T | -250.0℃~400.0℃ | -250.0~400.0℃: 0.6℃ | |||
N | -200.00℃~1300.0℃ | -200.0~100.0℃: 1.0℃     -100.0~900.0℃: 0.7℃     -900.0~1300.0℃: 0.8℃ | |||
B | 600℃~1820℃ | 1℃ | 600~800℃: 1.5℃       800~1820℃: 1.1℃ | ||
L | -200.0℃~900.0℃ | 0.1℃ | -200.0~0.0℃: 0.7℃      0.0~900.0℃: 0.5℃ | ||
U | -200.0℃~600.0℃ | 0.1℃ | -200.0~0.0℃: 0.7℃    0.0~600.0℃: 0.5℃ | ||
RTD | Pt100385 | -200.0℃~800.0℃ | 0.1℃ | -200.0~0.0℃: 0.3℃    0.0~400.0℃: 0.5℃    400.0~800.0℃: 0.8℃ | Using the ITS-90 temperature scale:  1. When the excitation current of Pt1Cu00, 50, and Cu10 is ± 0.5~3mA, and the excitation current is ± 0.1~0.5mA, an additional error of 0.5 ℃ is added. 2. The excitation current for Pt200, Pt500, and Pt1000 is ± 0.05~0.3mA, and the accuracy does not include lead resistance. |
Pt200385 | -200.0℃~630.0℃ | -200.0~100.0℃: 0.8℃  100.0~300.0℃: 0.9℃  300.0~630.0℃: 1.0℃ | |||
Pt500385 | -200.0℃~630.0℃ | -200.0~100.0℃: 0.4℃ 100.0℃~300.0℃: 0.9℃   300.0~630.0℃: 0.7℃ | |||
Pt1000385 | -200.0℃~630.0℃ | -200.0~100.0℃: 0.2℃   100.0~300.0℃: 0.5℃     300.0~630.0℃: 0.7℃ | |||
Cu10 | -100.0℃~260.0℃ | 0.8℃ | |||
Cu50 | -50.0℃~150.0℃ | 0.6℃ | |||
FREQ | 100Hz | 1.00Hz~110.00Hz | 0.1Hz | ±2ä¸ªå— | 1~11Vp-p square wave level accuracy ± 5% reading=0.5V, 50% duty cycle, load>100K Ω |
1KHz | 0.100KHz~1.100KHz | 1KHz | |||
10KHz | 1.0KHz~11.0KHz | 0.1KHz | |||
100KHz | 10KHz~110KHz | 2KHz | ±5ä¸ªå— | ||
PULSE | 100Hz | 1~100000cycles | 1cyc | ±2ä¸ªå— | 1~11Vp-p square wave level accuracy ± 5% reading=0.5V, 50% duty cycle, load>100K Ω |
1KHz | |||||
10KHz | |||||
SWITCH | 100Hz | 1.00Hz~110.00Hz | 0.01Hz | ±2ä¸ªå— | Field effect transistor switch, maximum switching voltage/current: ± 28V/50mA |
1KHz | 0.100KH~1.100KHz | 1Hz | |||
10KHz | 1.0KHz~11.0KHz | 0.1KHz | |||
100KHz | 10KHz~110KHz | 2KHz | ±5ä¸ªå— |
Q1:Â What is a Process Calibrator?
A1: A process calibrator is a device used to test, calibrate, and troubleshoot process instrumentation such as temperature sensors, pressure transmitters, and electrical signal sources. By simulating and measuring various signals, process calibrators enable engineers and technicians to validate system performance.
Q2: What are the types of process calibrators?
A2:Â Multifunction Calibrators - Capable of handling multiple types of signals including voltage, current, resistance, and frequency. Temperature Calibrators - Used specifically for thermocouples and RTDs to ensure precise temperature measurements. Pressure Calibrators - Designed for testing pressure-based instruments and ensuring accuracy in fluid systems. Loop Calibrators - Primarily used for 4-20 mA control loops in industrial automation systems.
Q3: How does a process calibrator work?
A3: A process calibrator is a multifunctional test tool used in industrial settings to simulate, measure, and source various process signals to calibrate and troubleshoot instruments.
Tips: When using the process calibrator, the following precautions should be taken: