All Categories
Menu Close

Digital Megger Insulation Tester, 500V/1000V/2500V/5000V

Digital high voltage megger tester with test voltages of 500V, 1000V, 2500V, and 5kV, measuring resistance range up to 1000G ohm for electrical equipment diagnostic testing and maintenance. Portable megger insulation tester has large backlight LCD display, easy to read and high accuracy.
SKU: SISCO-IRT-UT513
$952.30
i h
🚚 Free shipping
🔙 30-day returns
📅 Delivery: 7-12 days
Overview


sisco megger insulation tester can measure the insulation resistance of large transformers, generators, high-voltage motors and so on. Digital megger can be selected from the test voltages of 500, 1000, 2500V and 5000V, with the capabilities of testing insulation resistance up to 1000 GΩ, high performance and reliable.

Megger insulation tester with adapter jack

Megger resistance tester with special adapter jack

The high voltage megger tester is equipped with a special adapter jack, the instrument must be switched off when the adapter is inserted or unplugged.

  1. Active door
  2. Adapter jack button
  3. USB insertion hole
Megger insulation resistance tester with LCD display

Insulation resistance tester with LCD backlight display

The measurement data is displayed with functional symbols, the readings are clear at a glance and high-definition, and the data can be displayed in a backlight.

Applications

The insulation resistance tester is suitable for measuring the insulation resistance of various electrical equipment and insulating materials such as transformers, motors, cables, switches, electrical appliances, and for maintenance, testing and verification of various electrical equipment.

Insulation resistance tester application

Specs
Model SISCO-IRT-UT513
Insulation Resistance (Ω) Test voltage/accuracy 500V/1000V/2500V/5000V 0% ~ 20%
Measurement range/accuracy 500V 1 MΩ ~ 20 GΩ ±(3%+5)
1000V 2 MΩ ~ 40 GΩ ±(5%+5)
2500V 5 MΩ ~ 100 GΩ ±(3%+5)
5000V 10 MΩ ~ 1000 GΩ ±(3%+5)
Short-circuit current <1.8mA
DC Voltage (V) Test range/accuracy 600V ±(2%+5)
AC Voltage (V) Test range/accuracy 600V ±(2%+5)
Features Display 9999 counts
Auto ranging Yes
Auto power off Yes
Low battery indication Yes
Data storage 18
Comparison measurement Yes
PI Yes
DAR Yes
USB port Yes
LCD backlight Yes
Analog bar graph 30
Over-range warning Yes
High voltage indication Yes
Timing measurement (Around 15 min) Yes
General Power supply 1.5V battery (LR14) x 8
Display size 123mm x 58mm
Operating temperature 0℃ ~ 40℃ (32℉ ~ 104℉)
Storage Temperature -20℃ ~ 60℃ (-4℉ ~ 140℉)
Relative Humidity ≤85%RH @ 0℃ ~ 40℃ below;
≤90%RH @ -20℃ ~ 60℃
Product weight 2kg
Product size 202mm x 155mm x 94mm
Standard accessories * 2*single plug test lead with alligator clip (black and green), 1*double plug test lead with alligator clip (red), batteries, USB cabel, PC software CD

Note: * Batteries are Not Included for air shippment.

Insulation Resistance Tester Wiring Diagram

5000V megger insulation resistance test wiring diagram

FAQs

Q1: What is a insulation tester?
A1:
Insulation tester, also known as megohmmeter or meggers, are widely used to measure cables for generators, motors, power transformers, wiring, appliances and other electrical installations such as control, signal, communication and power ) insulation resistance. They are often used in routine maintenance procedures to indicate changes in the insulation resistance of a motor over months or years. Large changes in insulation resistance may indicate potential failures. Therefore, regular calibration of the megohmmeter is required to ensure that the meter itself has not changed over time.

Q2: What is insulation resistance?
A2: Insulation resistance is the DC resistance of the insulation under the specified conditions, that is, the DC voltage is applied to the dielectric, after a certain period of polarization, the resistance corresponding to the leakage current flowing through the dielectric is called insulation resistance. It is the most basic insulation index of electrical equipment and electrical circuit.

Q3: How to measure insulation resistance?
A3: 1. Connect all the lines according to the method measured by the insulation resistance tester. The connection between the measuring lead and the pipe is more suitable for the use of magnetic joints or clips, and the connection point must be free of rust.
2. The measuring instrument should be a 500V/500MΩ (the error here cannot be greater than 10%) insulation tester. Turn the handle of the megohmmeter to reach the specified speed for 10 seconds. The resistance value indicated by the megohmmeter stably is the insulation resistance value of the insulating joint (flange), which is required to be greater than 10 megohms.

Tips: How to choose a digital megger insulation tester?

The digital megger insulation tester has powerful functions and can cope with various complex situations on site, such as effectively eliminating interference, automatically tracking the most suitable test conditions, etc. Some digital meggers can also directly measure interference frequency and interference voltage. If you need an insulation tester with higher test accuracy, you can use a double clamp-on grounding resistance tester. For example, the grounding resistance measurement of grounding devices such as output pole towers, microwave towers, lightning rods and auxiliary devices (faucets, water pipe devices) with good grounding conditions, can use clamp-on type grounding resistance meter to measure the grounding resistance. For large-scale system grounding, network grounding, and soil resistivity tests, it is better to choose a ground resistance tester.

Warranty

Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.


What is covered?

SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.


What is not covered?

  • Product purchased from anyone other than a SISCO store or a SISCO authorized reseller.
  • Expendable parts.
  • Routine cleaning or normal cosmetic and mechanical wear.
  • Damage from misuse, abuse or neglect.
  • Damage from use of parts other than SISCO approved.
  • Damage from use outside the product’s usage or storage parameters.
  • Damage from use of parts not sold by SISCO.
  • Damage from modification or incorporation into other products.
  • Damage from repair or replacement of warranted parts by a service provider other than a SISCO authorized service provider.
  • Damage caused by the application environment not meeting the product usage requirements and the failure to perform preventive maintenance.
0.0 0
Write your own review Close
*
*