All Categories
    Menu Close

    LED Sound Level Meter, 30-130 dBA

    SISCO LED Sound Level Meter is equipped with an LED display screen, which can quickly and clearly display the measured sound pressure level value, and can read data in different light measurement environments. In addition to the sound pressure level detection function, it also has temperature, humidity and time display functions, which is suitable for more usage scenarios.
    SKU: SISCO-SLM-DM165A
    $95.69
    i h
    🚚 Free shipping
    πŸ”™ 30-day returns
    πŸ“… Delivery: 7-12 days
    Overview


    The noise level meter has a four-in-one function, with three modes of decibel (dB), temperature (℃/℉) and humidity (%) that can be switched, and a large LED high-definition screen display, which allows faster acquisition of monitoring data.




    Led sound level meter living room


    Fully Functional

    • Two temperature settings are available: Fahrenheit (℉) and Celsius (℃).
    • With sound pressure level, temperature, humidity, and time display functions, it can meet various usage needs.
    Led sound level meter office

    Quality Assurance

    • LCD high-definition colorful display, easy to read data.
    • Built-in rechargeable lithium battery, longer standby time.
    • Wall-mounted design saves space and has da ecorative effect.

     

     

    Applications

    A sound level meter is a device used to measure sound intensity. It is widely used in many fields such as environmental monitoring, industrial production, building design and construction, traffic management, occupational health and safety, etc. Measuring the sound intensity in different areas, helps planning departments understand and control urban noise pollution, and also provides data support for traffic planning and noise control. It is used to detect the noise generated by medical equipment during operation to ensure that the noise of medical equipment will not interfere with and harm patients and medical staff. It is used to detect the noise generated by fire-fighting facilities during operation to ensure that the noise of fire-fighting facilities will not interfere with and harm the surrounding environment and personnel. In times of crisis, it can promptly and effectively sound the alarm to guide people to escape.

    Sound level meter environmental monitoring

    Environmental Monitoring

    Sound level meter fire fetection

    Fire Fetection

    Sound level meter scientific research and education

    Research and Education

    Sound level meter architectural acoustics

    Architectural Acoustics

    Specs

    Β 

    Model SISCO-SLM-DM165A
    Display Method LED Screen
    Atmospheric Pressure 12.5 PSl ~ 15.4 PSI
    Sampling Time 1.5 Seconds
    Temperature Range -10℃~50℃ (14℉~122℉)
    Storage Temperature -10℃~60℃ (14℉~140℉)
    Relative Humidity 20%~85%
    Humidity Range 20%~85%
    Charging 2A 5V DC
    Battery 2000 mAh Lithium lon
    Concentration Unit Decibel dBA
    Measuring Range 30~130 dBA
    Accuracy Β±1.5 dBA
    Frequency Range 50Hz~8.5kHz
    Frequency Weighting A
    Resolution 0.1 dBA
    Weight 0.65kg
    Size 10.6Γ—3.5Γ—1.4 Inches

    Β 

    Structure Diagram

    Led sound level meter structure diagram

    1. Decibel Reading
    2. Power Button
    3. Left Button
    4. Sound Level lndicators
    5. Right Button
    6. Menu Button
    7. Microphone Sensor
    8. Temperature Level lndicators
    9. Time
    10. Humidity Reading
    11. Charging Input
    12. Temperasture Reading
    13. Positioning Sticker
    14. Screws

    Β 

    FAQs

    Q1: What is a noise detector?
    A1: Β Noise tester is an instrument used for noise detection and testing in public places such as work sites and squares. Factory noise monitoring Noise pollution is one of the environmental pollutions that have a greater impact. Higher decibel noise can even cause serious damage to people's eardrums and cause deafness. The application of the noise tester can provide the decibel that the noise reaches in order to take relevant measures to control and reduce the noise. The measurement unit of the sound level is decibels. The professional noise tester has a highly sensitive sensor, high accuracy, and a wide range of applications. It can be widely used for noise measurement in various environments. Sound level measuring instrument, collectively referred to as sound level meter.

    Q2: Sound level meter working principle
    A2: The sound level meter uses a microphone to convert the sound into an electrical signal, and then a preamplifier converts the impedance to match the microphone with the attenuator. The amplifier adds the output signal to the weighting network, performs frequency weighting on the signal (or an external filter), and then amplifies the signal to a certain amplitude through the attenuator and amplifier, and sends it to the effective value detector (or external press Level recorder), give the value of the noise level on the indicator head.

    Q3: How big is the decibel scale?
    A3: Sound is measured in decibels (dB). Whispering is about 30 decibels, normal conversation is about 60 decibels, and motorcycle engines run at about 95 decibels. Noise above 70 decibels for long periods of time may begin to damage your hearing. Loud noises above 120 dB can cause immediate damage to your ears.

    Tips: Is The Higher The Sensitivity of The Sound Level Meter, The Better?

    The higher the sensitivity of the sound level meter, the better. Instead, the appropriate sensitivity needs to be selected according to the actual measurement needs. The sensitivity of a sound level meter refers to the relationship between the change in the output signal of the sound level meter and the change in the input sound pressure. It describes the degree of response of the sound level meter to the change in sound pressure. It is an important performance parameter of the sound level meter and directly affects the accuracy of the measurement results. A highly sensitive sound level meter can capture subtle sound changes more accurately, thereby improving the accuracy of the measurement. However, different measurement tasks have different requirements for the sensitivity of the sound level meter. For example, in situations where extremely low sound intensities need to be measured, such as environmental noise monitoring or acoustic laboratory research, a highly sensitive sound level meter is a more appropriate choice because it can detect lower sound pressure levels. In some cases, a sensitivity that is too high may not be necessary and may even lead to unstable measurement results or introduce unnecessary noise.

    Warranty

    Thank you for buying industrial test and measurement equipment on SISCO.com, all products sold by SISCO and the partner cover a 12 months warranty, effective from the date of receiving the products.


    What is covered?

    SISCO is responsible for providing free spare parts, and free technical support to assist the customer to repair the defective products until the problem is solved.


    What is not covered?

    • Product purchased from anyone other than a SISCO store or a SISCO authorized reseller.
    • Expendable parts.
    • Routine cleaning or normal cosmetic and mechanical wear.
    • Damage from misuse, abuse or neglect.
    • Damage from use of parts other than SISCO approved.
    • Damage from use outside the product’s usage or storage parameters.
    • Damage from use of parts not sold by SISCO.
    • Damage from modification or incorporation into other products.
    • Damage from repair or replacement of warranted parts by a service provider other than a SISCO authorized service provider.
    • Damage caused by the application environment not meeting the product usage requirements and the failure to perform preventive maintenance.
    0.0 0
    Write your own review Close
    *
    *